  1. #Gx works 2 cc link setup verification#
  2. #Gx works 2 cc link setup software#
  3. #Gx works 2 cc link setup series#

If you have the correct controller, you can also export the symbol database to be imported into GT designer and use the symbols instead of the devices. Just entering the desired device number would be the simplest way to set up the interfacing between the PLC and the HMI, but it could get complicated when adding to the project later or if integrating into an existing system. When in designer and dropping in objects to control your system, you can either enter a device number (like D150 or M10) or use a label in some cases.

You can also go back if needed at any point.įigure 8 – Run Screen and Window Switching Devicesįigure 10 – Final Verification of Wizard Setup On the final window, you just should verify the setup and press the final “Next”. So next you will then set up the IP address settings and some screen switching and window controls words as well as a basic screen design theme.Īfter these three windows, you’re almost done with the creation of the new project. With this basic connection example, we are choosing to use an Ethernet connection.

This would be for the relatively new FX5 (also FX5U or FX5UC) series PLC.įigure 6 – Selection of Target ControllerĬheck out our unboxing of a FX-5 PLC here, as well as our first time programming it here. For this example, I chose an iQ-F series. Once you click next, verifying the model you want, you will then select the processor target type the HMI will be connecting to in your system. Here is the GS2107-WTBD is shown as one of the options.Ĭheck out our unboxing of a GS21 HMI here, as well as an overview of the entire line of Mitsubishi HMIs here. We then verify that the 7” (GS2107) model we want is in the list. In the next step, you will select the type/model you are planning to use, being sure that the model you want to use is shown in the “Model:” box after you select the series (GOT2000, GOT1000, or GS Simple series).įor this example, we will pick a GS Series model. Simply stepping through the project creation wizard will get you a nice easy intuitive start. The vertical display setup is good for mounting in the side of an enclosure or maybe for easier display of some graphics that are better viewable when tall instead of wide. The first step is where you can select items that will set the unit up for a traditional horizontal display or maybe a vertical display. The new project wizard will open up and ask for you to press “Next” to start cycling through the wizard’s steps.

You can also just simply press the “New…” button on the dialog window that pops up when the software starts. Once the application has started, we'll select “Project” and click “New”. I'n today's article we'll start our new HMI application by creating a project in GT Designer 3 by way of the “New Project Wizard.” You can create a project that just does the simplest of things from push buttons and numeric displays, to a combination of more advanced data logging displays or using background scripting that copies, renames, and deletes files that are written over an FTP connection from another non-Mitsubishi controller. In today's article I walk through the initial steps of setting up a new Mitsubishi HMI project, including creating a project, importing the PLC symbol database, and more.įocusing on the same principle that you can make something difficult or simple, the GOT Designer software for Mitsubishi HMIs can let you do just that.